Our Recommendation

VERKOPLUS 15w40 LD

Make
JOHN DEERE
Model
6135 (Tier3 PowerTech Series)
Engine
D / DT
New Search Print
Application
Recommendation
Capacity (ltr)
Engine (D / DT)
1
VERKOPLUS 15w40 LD (a, b, c, d, e, f, g, h)
2
VERKOPLUS 15w40 MSA
Coolant
VERKOL TRUCK 50% (i)

Lubricant / Capacity Notes

a.
Oil change interval can be extended using John Deere PLUS-50 or E6/E7 with specified John Deere filters: fuel sulphur level <0.1%, 375 hours with standard oil pan, 500 hours withextended drain oil pan; fuel sulphur 0.1% to 0.5%, 250 hours; fuel sulphur 0.5% to 1% 150 hours
b.
Oil drain interval using CI-4, E4 or E5: fuel sulphur level < 0.1%, 250 hours; fuel sulphur 0.1% to 0.5%, 150 hours; fuel sulphur 0.5% to 1%, 100 hours
c.
During engine run-in use John Deere Engine Break-in Oil. Alternatively engine oils to CE/E1/D4 may be used during the first 100 hours of engine use
d.
Alternative recommendations, -40°C to 50°C: CI-4/E4/E5 0W-40
e.
Alternative recommendations, -30°C to 40°C: VERATEK 5w30 / EXTREM NG 5w30
f.
Alternative recommendations, -25°C to 50°C: VERATEK 10w40 / EXTREM NG 10w40 / TITANIUM NG 10w40 UHPD
g.
Alternative recommendations, -25°C to 40°C: VERKOPLUS 10w30 MSA
h.
Alternative recommendations, -20°C to 50°C: VERKOPLUS 15w40 LD / VERKOPLUS 15w40 MSA
i.
Cooling systems: Do not use automotive type coolants. John Deere products strongly recommended. Use VERKOL TRUCK 50% at a concentration of 40% mixture of concentrate with quality water and approved supplemental coolant additives for all year operation. Alternative specification; low silicate ethylene glycol based coolant for heavy duty diesel engines to VERKOL TRUCK 50%TM D5345 (pre-diluted) or VERKOL TRUCK 50%TM D4985 (concentrate) plus supplemental coolant additives

General Notes

1.
Fuel sulphur content greater than 0.5% results in oil change intervals reduced by half

Oil Change Intervals

There is no Oil Change Interval data to display for this model