Our Recommendation

VERATEK 5w30

Make
DOOSAN
Model
9 Series D45SC-9 (DM03V) (9 Series)
Engine
D
Year
2021-2023
New Search Print
Application
Recommendation
Capacity (ltr)
Engine (D)
VERATEK 5w30 (c, d, e, f, g, h, i, j, k, l)
12.6 (a, b)
Transmission (Automatic)
VESTA TD 3 (m)
Coolant
VERKOL TRUCK 50% (n, o, p, q)
13.0
Brake system
1
VESTA HM 32 (r)
0.6
2
VESTA HLPD 32
3
VESTA HLP 32
Hydraulic system
1
VESTA HM 32 (s, t, u)
73.0
2
VESTA HLPD 32
3
VESTA HLP 32
Grease points
  (v)

Lubricant / Capacity Notes

a.
Engine sump, including filter, 12.6 litres
b.
Oil filter change interval (first change only), 50.0 h
c.
-30°C to 30°C
d.
Alternative recommendations, Preferred lubricant specification, -30°C to 40°C: CJ-4 5W-40
e.
Alternative recommendations, Preferred lubricant specification, -30°C to 30°C: CK-4 5W-30
f.
Alternative recommendations, Preferred lubricant specification, -20°C to 40°C: CK-4 10W-40
g.
Alternative recommendations, Preferred lubricant specification, -20°C to 30°C: CK-4 10W-30
h.
Alternative recommendations, Preferred lubricant specification, -15°C to 40°C: CK-4 15W-40
i.
Alternative recommendations, -30°C to 40°C: CK-4 5W-40
j.
Alternative recommendations, -20°C to 40°C: VERATEK 10w40
k.
Alternative recommendations, -20°C to 30°C: VERKOPLUS 10w30 MSA
l.
Alternative recommendations, -15°C to 40°C: VERKOPLUS 15w40 MSA
m.
-20°C to 50°C
n.
De-ionised water with 60% anti-freeze & >-51°C
o.
Alternative recommendations, De-ionised water with 30% anti-freeze, >-15°C: VERKOL TRUCK 50%
p.
Alternative recommendations, De-ionised water with 40% anti-freeze, >-23°C: VERKOL TRUCK 50%
q.
Alternative recommendations, De-ionised water with 50% anti-freeze, >-37°C: VERKOL TRUCK 50%
r.
-20°C to 30°C
s.
-20°C to 30°C
t.
Alternative recommendations, -10°C to 40°C: VESTA HM 46 / VESTA HLPD 46 / VESTA HLP 46
u.
Alternative recommendations, 0°C to 50°C: VESTA HM 68 / VESTA HLP 68
v.
Alternative recommendations, Cold climates: GrLiM3-5% 1; GrLiM3-5% 0

General Notes

There are no notes to display for this model

Oil Change Intervals

Coolant
Months Max
12
Hours Max
2000
Hydraulic system
Months Max
15
Hours Max
2500