EXTREM NG 10w40

Make
SCANIA
Model
S 580 (DC16.106) Chassis Cab 8x2/4
Engine
D
Year
2016-
New Search Print
Application
Recommendation
Capacity (ltr)
Engine (D)
1
EXTREM NG 10w40 (c, d, e)
43.0 / 44.6 (a, b)
2
VERKOL 10w40 TD MAX
Retarder
1
VERKOPLUS 15w40 LD (f, g, h)
7.7
2
VERKOPLUS 15w40 MSA
Transmission (Semi-automatic)
  (i, j, k)
30.0
Transmission (Automatic) (Code: GA766/R)
  (n, o)
20.0 / 20.9 (l, m)
Transmission (Automatic) (Code: GA867/R)
  (r, s)
34.0 / 34.9 (p, q)
Power take-off (Code: EK730, or Code: EK740, or Code: EK750)
VERKOL GT-8/75w90 (u, v, w, x, y, z)
3.0 (t)
Power take-off (Code: EK630, or Code: EK640)
VERKOL GT-8/75w90 (bb, bc, bd, be, bf, bg)
2.0 (ba)
Transmission (Automatic) (Code: GA866/R)
  (bj, bk)
34.0 / 34.9 (bh, bi)
Transmission (Automatic) (Code: GA765/R)
  (bn, bo)
20.0 / 20.9 (bl, bm)
Transmission (Automatic) (Code: GA767/R)
  (bq, br)
20.0 / 20.9 (bp)
Axle (Code: RBP731)
  (bu, bv, bw, bx, by, bz, ca)
0.8 / 17.0 (bs, bt)
Axle (Code: RBP835)
  (cd, ce, cf, cg, ch, ci, cj)
2.0 / 12.0 (cb, cc)
Axle (Code: AD 400 TZ)
VERKOL GT-8/75w90 (cm, cn, co, cp, cq, cr, cs, ct, cu, cv, cw, cx, cy, cz)
12.5 / 13.0 (ck, cl)
Axle (Code: AD 400 TAP)
VERKOL GT-8/75w90 (dc, dd, de, df, dg, dh, di, dj, dk, dl, dm, dn, do, dp)
2.0 / 9.3 (da, db)
Axle (Code: R665)
  (dq, dr, ds, dt, du, dv, dw)
12.5
Axle (Code: AD 401 SA)
VERKOL GT-8/75w90 (dz, ea, eb, ec, ed, ee, ef, eg, eh, ei, ej, ek, el, em)
12.5 / 13.0 (dx, dy)
Axle (Code: RP736)
  (en, eo, ep, eq, er, es, et)
9.3
Axle (Code: RBP736)
  (ew, ex, ey, ez, fa, fb, fc)
0.8 / 11.8 (eu, ev)
Axle (Code: AD 200 SA)
VERKOL GT-8/75w90 (fd, fe, ff, fg, fh, fi, fj, fk, fl, fm, fn, fo, fp, fq)
12.5
Axle (Code: AD 400 SZ)
VERKOL GT-8/75w90 (ft, fu, fv, fw, fx, fy, fz, ga, gb, gc, gd, ge, gf, gg)
12.5 / 13.0 (fr, fs)
Axle (Code: R782)
  (gh, gi, gj, gk, gl, gm, gn)
12.5
Axle (Code: RBP730)
  (gq, gr, gs, gt, gu, gv, gw)
2.0 / 14.0 (go, gp)
Axle (Code: RP835)
  (gz, ha, hb, hc, hd, he, hf)
2.0 / 9.3 (gx, gy)
Axle (Code: RP735)
  (hi, hj, hk, hl, hm, hn)
2.0 / 8.0 (hg, hh)
Axle (Code: AD 400 TA)
VERKOL GT-8/75w90 (ho, hp, hq, hr, hs, ht, hu, hv, hw, hx, hy, hz, ia, ib)
12.5
Axle (Code: R660)
  (ic, id, ie, if, ig, ih, ii)
12.5
Axle (Code: AD 400 SA)
VERKOL GT-8/75w90 (il, im, in, io, ip, iq, ir, is, it, iu, iv, iw, ix, iy)
12.5 / 13.0 (ij, ik)
Axle (Code: AD 500 TZP)
VERKOL GT-8/75w90 (jb, jc, jd, je, jf, jg, jh, ji, jj, jk, jl, jm, jn, jo)
2.0 / 9.3 (iz, ja)
Axle (Code: RB662)
  (jp, jq, jr, js, jt, ju, jv)
14.0
Axle (Code: RBP735)
  (jy, jz, ka, kb, kc, kd, ke)
2.0 / 11.2 (jw, jx)
Axle (Code: R885)
  (kf, kg, kh, ki, kj, kk, kl)
13.0
Axle (Code: R780)
  (km, kn, ko, kp, kq, kr, ks)
12.5
Axle (Code: R560)
  (kt, ku, kv, kw, kx, ky, kz)
12.5
Axle (Code: AD 400 SAP)
VERKOL GT-8/75w90 (la, lb, lc, ld, le, lf, lg, lh, li, lj, lk, ll, lm, ln)
9.3
Coolant
  (lr)
45.0 / 55.0 / 57.0 (lo, lp, lq)
Power Steering
VESTA TD 2 (ls)
Gearbox hydraulic control
VESTA TD 2 (lt)
Hydraulic system (SCANIA & Hydraulic system: 2-way tipper truck)
1
MULTIVESTA OP
55.0
2
VESTA HV 46
Hydraulic system (SCANIA & Hydraulic system: tipper truck)
VESTA HVS 15 (lu, lv, lw, lx)
79.0
Hydraulic system (SCANIA & Hydraulic system: tipper truck)
VESTA HVS 15 (ly, lz, ma, mb)
100
Cab Tilt System
 
Grease points
QUAKERTEK ASTURUS 2 (mc)
Air conditioning
 
(md, me, mf, mg)
Compressor
 
(mh, mi, mj, mk)
2-way tipper system
1
MULTIVESTA OP
2
VESTA HV 46
Tail lift
VESTA HV 22 (ml)
DEF tank
 
Rear tipper system
VESTA HV 22 (mm, mn, mo, mp)

Lubricant / Capacity Notes

a.
Engine sump, without filter, 43.0 litres
b.
Engine sump, including filter, 44.6 litres
c.
>-25°C
d.
Alternative recommendations, >-30°C: EO SCA LDF3 0W-40; EO SCA LDF3 5W-40
e.
Alternative recommendations, >-15°C: EO SCA LDF3 15W-40
f.
Standard interval
g.
Alternative recommendations, Extended interval: VERKOL SAE 50 TO-4 / VERKOL SAE 30 TO-4 / VERKOL SAE 10w TO-4; VESTA TD 3
h.
Alternative recommendations, Standard interval: E7 10W-30; VESTA TD 3 / VESTA C4 10w30 / VESTA TD 2; VESTA TD 3 / VESTA TD 2
i.
>-5°C
j.
Alternative recommendations, <-5°C: GO ZEF 02H 20W
k.
Alternative recommendations, >0°C: GO ZEF 02H 40
l.
Without retarder, 20.0 litres
m.
With retarder, 20.9 litres
n.
Extended interval
o.
Alternative recommendations, Standard interval: ATF ALL TES389
p.
Without retarder, 34.0 litres
q.
With retarder, 34.9 litres
r.
Extended interval
s.
Alternative recommendations, Standard interval: ATF ALL TES389
t.
Approximate value(s), 3.0 litres
u.
All temperatures & standard interval
v.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2G 75W-90
w.
Alternative recommendations, Standard interval, >-25°C: GO SCA STO1 75W-140
x.
Alternative recommendations, Standard interval, -15°C to 20°C: VERKOL GT-8/80w90 EP
y.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 80W-140
z.
Alternative recommendations, Standard interval, >0°C: GO SCA STO1 85W-140
ba.
Approximate value(s), 2.0 litres
bb.
All temperatures & standard interval
bc.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2G 75W-90
bd.
Alternative recommendations, Standard interval, >-25°C: GO SCA STO1 75W-140
be.
Alternative recommendations, Standard interval, -15°C to 20°C: VERKOL GT-8/80w90 EP
bf.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 80W-140
bg.
Alternative recommendations, Standard interval, >0°C: GO SCA STO1 85W-140
bh.
Without retarder, 34.0 litres
bi.
With retarder, 34.9 litres
bj.
Extended interval
bk.
Alternative recommendations, Standard interval: ATF ALL TES389
bl.
Without retarder, 20.0 litres
bm.
With retarder, 20.9 litres
bn.
Standard interval
bo.
Alternative recommendations, Extended interval: ATF ALL TES295
bp.
With retarder, 20.9 litres
bq.
Extended interval
br.
Alternative recommendations, Standard interval: ATF ALL TES389
bs.
Differential, 17.0 litres
bt.
Reduction hub, 0.8 litres
bu.
All temperatures & standard interval
bv.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
bw.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
bx.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
by.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
bz.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
ca.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
cb.
Reduction hub, 2.0 litres
cc.
Differential, 12.0 litres
cd.
All temperatures & standard interval
ce.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
cf.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
cg.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
ch.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ci.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
cj.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
ck.
R753/885 differentials, 13.0 litres
cl.
R560/660/665/780/782 differentials, 12.5 litres
cm.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
cn.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
co.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
cp.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
cq.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
cr.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
cs.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
ct.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
cu.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
cv.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
cw.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
cx.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
cy.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
cz.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
da.
Reduction hub, 2.0 litres
db.
Differential, 9.3 litres
dc.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
dd.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
de.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
df.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
dg.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
dh.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
di.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
dj.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
dk.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
dl.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
dm.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
dn.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
do.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
dp.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
dq.
All temperatures & standard interval
dr.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ds.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
dt.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
du.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
dv.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
dw.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
dx.
R560/660/665/780/782 differentials, 12.5 litres
dy.
R753/885 differentials, 13.0 litres
dz.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
ea.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
eb.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
ec.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
ed.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
ee.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
ef.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
eg.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
eh.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
ei.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
ej.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
ek.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
el.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
em.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
en.
All temperatures & standard interval
eo.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ep.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
eq.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
er.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
es.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
et.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
eu.
Reduction hub, 0.8 litres
ev.
Differential, 11.8 litres
ew.
All temperatures & standard interval
ex.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ey.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
ez.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
fa.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
fb.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
fc.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
fd.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
fe.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
ff.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
fg.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
fh.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
fi.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
fj.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
fk.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
fl.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
fm.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
fn.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
fo.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
fp.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
fq.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
fr.
R560/660/665/780/782 differentials, 12.5 litres
fs.
R753/885 differentials, 13.0 litres
ft.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
fu.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
fv.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
fw.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
fx.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
fy.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
fz.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
ga.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
gb.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
gc.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
gd.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
ge.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
gf.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
gg.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
gh.
All temperatures & standard interval
gi.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
gj.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
gk.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
gl.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
gm.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
gn.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
go.
Differential, 14.0 litres
gp.
Reduction hub, 2.0 litres
gq.
All temperatures & standard interval
gr.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
gs.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
gt.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
gu.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
gv.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
gw.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
gx.
Differential, 9.3 litres
gy.
Reduction hub, 2.0 litres
gz.
All temperatures & standard interval
ha.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
hb.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
hc.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
hd.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
he.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
hf.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
hg.
Reduction hub, 2.0 litres
hh.
Differential, 8.0 litres
hi.
All temperatures & standard interval
hj.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-110; GO SCA STO2A 75W-140
hk.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
hl.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
hm.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
hn.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
ho.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
hp.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
hq.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
hr.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
hs.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
ht.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
hu.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
hv.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
hw.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
hx.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
hy.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
hz.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
ia.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
ib.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
ic.
All temperatures & standard interval
id.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ie.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
if.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
ig.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ih.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
ii.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
ij.
R560/660/665/780/782 differentials, 12.5 litres
ik.
R753/885 differentials, 13.0 litres
il.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
im.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
in.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
io.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
ip.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
iq.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
ir.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
is.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
it.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
iu.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
iv.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
iw.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
ix.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
iy.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
iz.
Differential, 9.3 litres
ja.
Reduction hub, 2.0 litres
jb.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
jc.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
jd.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
je.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
jf.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
jg.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
jh.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
ji.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
jj.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
jk.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
jl.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
jm.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
jn.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
jo.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
jp.
All temperatures & standard interval
jq.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
jr.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
js.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
jt.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ju.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
jv.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
jw.
Reduction hub, 2.0 litres
jx.
Differential, 11.2 litres
jy.
All temperatures & standard interval
jz.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ka.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
kb.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
kc.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
kd.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
ke.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
kf.
All temperatures & standard interval
kg.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
kh.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
ki.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
kj.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
kk.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
kl.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
km.
All temperatures & standard interval
kn.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ko.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
kp.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
kq.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
kr.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
ks.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
kt.
All temperatures & standard interval
ku.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
kv.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
kw.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
kx.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ky.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
kz.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
la.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
lb.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
lc.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
ld.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
le.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
lf.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
lg.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
lh.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
li.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
lj.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
lk.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
ll.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
lm.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
ln.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
lo.
Without oil cooler, 45.0 litres
lp.
With retarder, 57.0 litres
lq.
With oil cooler, 55.0 litres
lr.
>-37°C
ls.
Alternative recommendations: VESTA TD 3; ATF-D6
lt.
Alternative recommendations: ATF-D2E; VESTA TD 3
lu.
-40°C to -10°C
lv.
Alternative recommendations, Northern Europe: VESTA HV 22
lw.
Alternative recommendations, Southern Europe: VESTA HV 32
lx.
Alternative recommendations, 40°C to 50°C: MULTIVESTA OP / VESTA HV 46
ly.
-40°C to -10°C
lz.
Alternative recommendations, Northern Europe: VESTA HV 22
ma.
Alternative recommendations, Southern Europe: VESTA HV 32
mb.
Alternative recommendations, 40°C to 50°C: MULTIVESTA OP / VESTA HV 46
mc.
Lithium-based
md.
Refrigerant; With additional air conditioning, 1,450 g
me.
Refrigerant; Without additional air conditioning, 1,000 - 1,100 g
mf.
Refrigerant; Double Cab, 1,850 - 1,950 g
mg.
Air-conditioning compressor oil, system total, 240 ml
mh.
Refrigerant; With additional air conditioning, 1,450 g
mi.
Refrigerant; Without additional air conditioning, 1,000 - 1,100 g
mj.
Refrigerant; Double Cab, 1,850 - 1,950 g
mk.
Air-conditioning compressor oil, system total, 240 ml
ml.
Alternative recommendations: VESTA HV 32; MULTIVESTA OP / VESTA HV 46
mm.
Northern Europe
mn.
Alternative recommendations, Southern Europe: VESTA HV 32
mo.
Alternative recommendations, <-10°C: VESTA HVS 15
mp.
Alternative recommendations, >40°C: MULTIVESTA OP / VESTA HV 46

General Notes

There are no notes to display for this model

Oil Change Intervals

There is no Oil Change Interval data to display for this model