Close Print

Our Recommendation

Make
SCANIA
Model
S 450 (DC13.148) Chassis Cab 6x2
Engine
D
Year
2016-
Application
Recommendation
Capacity (ltr)
Engine (D)
  (a)
41.0
Transmission (Manual) (Code: GRS895/R)
  (b, c, d, e, f, g)
13.0 - 15.0
Transmission (Manual) (Code: G670)
  (h, i)
6.8
Transmission (Manual) (Code: GRSO925/R)
  (j, k, l, m, n, o)
14.5 - 17.5
Transmission (Manual) (Code: GR905/R)
  (p, q, r, s, t, u)
14.5 - 17.5
Transmission (Manual) (Code: GRSO900/R)
  (v, w, x, y, z, ba)
17.0
Transmission (Semi-automatic)
  (bb, bc, bd)
30.0
Transmission (Automatic) (Code: GA766/R)
  (bg, bh)
20.0 / 20.9 (be, bf)
Transmission (Automatic) (Code: GA867/R)
  (bk, bl)
34.0 / 34.9 (bi, bj)
Transmission (Automatic) (Code: GA866/R)
  (bo, bp)
34.0 / 34.9 (bm, bn)
Transmission (Automatic) (Code: GA765/R)
  (bs, bt)
20.0 / 20.9 (bq, br)
Transmission (Manual) (Code: GR801/R)
  (bw, bx, by, bz, ca, cb)
11.0 / 12.0 (bu, bv)
Transmission (Automatic) (Code: GA767/R)
  (cd, ce)
20.0 / 20.9 (cc)
Retarder
1
VERKOPLUS 15w40 LD (cf, cg, ch)
7.7
2
VERKOPLUS 15w40 MSA
Transmission (Manual) (Code: GRS900/R)
  (ci, cj, ck, cl, cm, cn)
17.0
Transmission (Manual) (Code: GRSO905/R)
  (co, cp, cq, cr, cs, ct)
14.5 - 17.5
Transmission (Manual) (Code: GR875/R)
  (cu, cv, cw, cx, cy, cz)
13.0 - 15.0
Transmission (Manual) (Code: GRS890/R)
  (da, db, dc, dd, de, df)
17.0
Transmission (Manual) (Code: GRS905/R)
  (dg, dh, di, dj, dk, dl)
14.5 - 17.5
Transmission (Manual) (Code: GRS920/R)
  (dm, dn, do, dp, dq, dr)
17.0
Transmission (Manual) (Code: GR900/R)
  (ds, dt, du, dv, dw, dx)
17.0
Axle (Code: RBP731)
  (ea, eb, ec, ed, ee, ef, eg)
0.8 / 17.0 (dy, dz)
Axle (Code: RBP835)
  (ej, ek, el, em, en, eo, ep)
2.0 / 12.0 (eh, ei)
Axle (Code: AD 400 TZ)
VERKOL GT-8/75w90 (es, et, eu, ev, ew, ex, ey, ez, fa, fb, fc, fd, fe, ff)
12.5 / 13.0 (eq, er)
Axle (Code: R665)
  (fg, fh, fi, fj, fk, fl, fm)
12.5
Axle (Code: AD 400 TAP)
VERKOL GT-8/75w90 (fp, fq, fr, fs, ft, fu, fv, fw, fx, fy, fz, ga, gb, gc)
2.0 / 9.3 (fn, fo)
Axle (Code: RP736)
  (gd, ge, gf, gg, gh, gi, gj)
9.3
Axle (Code: AD 401 SA)
VERKOL GT-8/75w90 (gm, gn, go, gp, gq, gr, gs, gt, gu, gv, gw, gx, gy, gz)
12.5 / 13.0 (gk, gl)
Axle (Code: AD 200 SA)
VERKOL GT-8/75w90 (ha, hb, hc, hd, he, hf, hg, hh, hi, hj, hk, hl, hm, hn)
12.5
Axle (Code: RBP736)
  (hq, hr, hs, ht, hu, hv, hw)
0.8 / 11.8 (ho, hp)
Axle (Code: AD 400 SZ)
VERKOL GT-8/75w90 (hz, ia, ib, ic, id, ie, if, ig, ih, ii, ij, ik, il, im)
12.5 / 13.0 (hx, hy)
Axle (Code: R782)
  (in, io, ip, iq, ir, is, it)
12.5
Axle (Code: RBP730)
  (iw, ix, iy, iz, ja, jb, jc)
2.0 / 14.0 (iu, iv)
Axle (Code: AD 400 SA)
VERKOL GT-8/75w90 (jf, jg, jh, ji, jj, jk, jl, jm, jn, jo, jp, jq, jr, js)
12.5 / 13.0 (jd, je)
Axle (Code: RP835)
  (jv, jw, jx, jy, jz, ka, kb)
2.0 / 9.3 (jt, ju)
Axle (Code: AD 500 TZP)
VERKOL GT-8/75w90 (ke, kf, kg, kh, ki, kj, kk, kl, km, kn, ko, kp, kq, kr)
2.0 / 9.3 (kc, kd)
Axle (Code: AD 400 TA)
VERKOL GT-8/75w90 (ks, kt, ku, kv, kw, kx, ky, kz, la, lb, lc, ld, le, lf)
12.5
Axle (Code: R660)
  (lg, lh, li, lj, lk, ll, lm)
12.5
Axle (Code: RP735)
  (lp, lq, lr, ls, lt, lu)
2.0 / 8.0 (ln, lo)
Axle (Code: RB662)
  (lv, lw, lx, ly, lz, ma, mb)
14.0
Axle (Code: RBP735)
  (me, mf, mg, mh, mi, mj, mk)
2.0 / 11.2 (mc, md)
Axle (Code: R885)
  (ml, mm, mn, mo, mp, mq, mr)
13.0
Axle (Code: R780)
  (ms, mt, mu, mv, mw, mx, my)
12.5
Axle (Code: AD 400 SAP)
VERKOL GT-8/75w90 (mz, na, nb, nc, nd, ne, nf, ng, nh, ni, nj, nk, nl, nm)
9.3
Axle (Code: R560)
  (nn, no, np, nq, nr, ns, nt)
12.5
Coolant
  (nu)
40.0
Power Steering (THP)
VESTA TD 2 (nv)
1.1
Power Steering (ZF & Code: ZF8098)
VESTA TD 2 (nw)
3.8
Power Steering (ZF & Code: ZF8099)
VESTA TD 2 (nx)
4.7
Power Steering (SCANIA)
VESTA TD 2 (ny)
Gearbox hydraulic control
VESTA TD 2 (nz)
Hydraulic system (SCANIA & Tail lift)
VESTA HV 22 (oa)
Hydraulic system (SCANIA & Hydraulic system: 2-way tipper truck)
1
MULTIVESTA OP
55.0
2
VESTA HV 46
Hydraulic system (SCANIA & Hydraulic system: tipper truck)
VESTA HVS 15 (ob, oc, od, oe)
79.0
Hydraulic system (SCANIA & Hydraulic system: 2-way tipper truck)
1
MULTIVESTA OP
47.0
2
VESTA HV 46
Hydraulic system (SCANIA & Hydraulic system: tipper truck)
VESTA HVS 15 (of, og, oh, oi)
100
Cab Tilt System
 
Grease points
QUAKERTEK ASTURUS 2 (oj)
Air conditioning
 
(ok, ol, om, on)
Compressor
 
(oo, op, oq, or)
2-way tipper system
1
MULTIVESTA OP
2
VESTA HV 46
Tail lift
VESTA HV 22 (os)
DEF tank
 
Rear tipper system
VESTA HV 22 (ot, ou, ov, ow)

General Notes

There are no notes to display for this model

Lubricant / Capacity Notes

a.
-25°C to 10°C
b.
Extended interval & >-35°C
c.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
d.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
e.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
f.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
g.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
h.
>-40°C
i.
Alternative recommendations, >-40°C: GO ZEF 02E 75W; GO ZEF 02E 75W-85; GO ZEF 02E 75W-90
j.
Extended interval & >-35°C
k.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
l.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
m.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
n.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
o.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
p.
Extended interval & >-35°C
q.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
r.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
s.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
t.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
u.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
v.
Extended interval & >-35°C
w.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
x.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
y.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
z.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
ba.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
bb.
>-5°C
bc.
Alternative recommendations, <-5°C: GO ZEF 02H 20W
bd.
Alternative recommendations, >0°C: GO ZEF 02H 40
be.
Without retarder, 20.0 litres
bf.
With retarder, 20.9 litres
bg.
Extended interval
bh.
Alternative recommendations, Standard interval: ATF ALL TES389
bi.
Without retarder, 34.0 litres
bj.
With retarder, 34.9 litres
bk.
Extended interval
bl.
Alternative recommendations, Standard interval: ATF ALL TES389
bm.
Without retarder, 34.0 litres
bn.
With retarder, 34.9 litres
bo.
Extended interval
bp.
Alternative recommendations, Standard interval: ATF ALL TES389
bq.
Without retarder, 20.0 litres
br.
With retarder, 20.9 litres
bs.
Standard interval
bt.
Alternative recommendations, Extended interval: ATF ALL TES295
bu.
With oil cooler, 11.0 litres
bv.
Air cooling, 12.0 litres
bw.
Extended interval & >-35°C
bx.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
by.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
bz.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
ca.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
cb.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
cc.
With retarder, 20.9 litres
cd.
Extended interval
ce.
Alternative recommendations, Standard interval: ATF ALL TES389
cf.
Standard interval
cg.
Alternative recommendations, Extended interval: VERKOL SAE 50 TO-4 / VERKOL SAE 30 TO-4 / VERKOL SAE 10w TO-4; VESTA TD 3
ch.
Alternative recommendations, Standard interval: E7 10W-30; VESTA TD 3 / VESTA C4 10w30 / VESTA TD 2; VESTA TD 3 / VESTA TD 2
ci.
Extended interval & >-35°C
cj.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
ck.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
cl.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
cm.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
cn.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
co.
Extended interval & >-35°C
cp.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
cq.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
cr.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
cs.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
ct.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
cu.
Extended interval & >-35°C
cv.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
cw.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
cx.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
cy.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
cz.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
da.
Extended interval & >-35°C
db.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
dc.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
dd.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
de.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
df.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
dg.
Extended interval & >-35°C
dh.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
di.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
dj.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
dk.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
dl.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
dm.
Extended interval & >-35°C
dn.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
do.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
dp.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
dq.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
dr.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
ds.
Extended interval & >-35°C
dt.
Alternative recommendations, Extended interval, >-20°C: GO SCA STO2G 80W-90
du.
Alternative recommendations, Extended interval, >-5°C: GO SCA STO2G 85W-90
dv.
Alternative recommendations, Standard interval, >-35°C: GO SCA STO1G 75W-90
dw.
Alternative recommendations, Standard interval, >-20°C: GO SCA STO1G 80W-90
dx.
Alternative recommendations, Standard interval, >-5°C: GO SCA STO1G 85W-90
dy.
Differential, 17.0 litres
dz.
Reduction hub, 0.8 litres
ea.
All temperatures & standard interval
eb.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ec.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
ed.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
ee.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ef.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
eg.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
eh.
Reduction hub, 2.0 litres
ei.
Differential, 12.0 litres
ej.
All temperatures & standard interval
ek.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
el.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
em.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
en.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
eo.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
ep.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
eq.
R753/885 differentials, 13.0 litres
er.
R560/660/665/780/782 differentials, 12.5 litres
es.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
et.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
eu.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
ev.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
ew.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
ex.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
ey.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
ez.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
fa.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
fb.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
fc.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
fd.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
fe.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
ff.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
fg.
All temperatures & standard interval
fh.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
fi.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
fj.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
fk.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
fl.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
fm.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
fn.
Reduction hub, 2.0 litres
fo.
Differential, 9.3 litres
fp.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
fq.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
fr.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
fs.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
ft.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
fu.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
fv.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
fw.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
fx.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
fy.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
fz.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
ga.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
gb.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
gc.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
gd.
All temperatures & standard interval
ge.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
gf.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
gg.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
gh.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
gi.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
gj.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
gk.
R560/660/665/780/782 differentials, 12.5 litres
gl.
R753/885 differentials, 13.0 litres
gm.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
gn.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
go.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
gp.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
gq.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
gr.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
gs.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
gt.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
gu.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
gv.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
gw.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
gx.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
gy.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
gz.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
ha.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
hb.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
hc.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
hd.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
he.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
hf.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
hg.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
hh.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
hi.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
hj.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
hk.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
hl.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
hm.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
hn.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
ho.
Reduction hub, 0.8 litres
hp.
Differential, 11.8 litres
hq.
All temperatures & standard interval
hr.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
hs.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
ht.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
hu.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
hv.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
hw.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
hx.
R560/660/665/780/782 differentials, 12.5 litres
hy.
R753/885 differentials, 13.0 litres
hz.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
ia.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
ib.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
ic.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
id.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
ie.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
if.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
ig.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
ih.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
ii.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
ij.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
ik.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
il.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
im.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
in.
All temperatures & standard interval
io.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
ip.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
iq.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
ir.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
is.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
it.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
iu.
Differential, 14.0 litres
iv.
Reduction hub, 2.0 litres
iw.
All temperatures & standard interval
ix.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
iy.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
iz.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
ja.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
jb.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
jc.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
jd.
R560/660/665/780/782 differentials, 12.5 litres
je.
R753/885 differentials, 13.0 litres
jf.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
jg.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
jh.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
ji.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
jj.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
jk.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
jl.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
jm.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
jn.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
jo.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
jp.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
jq.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
jr.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
js.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
jt.
Differential, 9.3 litres
ju.
Reduction hub, 2.0 litres
jv.
All temperatures & standard interval
jw.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
jx.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
jy.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
jz.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ka.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
kb.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
kc.
Differential, 9.3 litres
kd.
Reduction hub, 2.0 litres
ke.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
kf.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
kg.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
kh.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
ki.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
kj.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
kk.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
kl.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
km.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
kn.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
ko.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
kp.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
kq.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
kr.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
ks.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
kt.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
ku.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
kv.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
kw.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
kx.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
ky.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
kz.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
la.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
lb.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
lc.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
ld.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
le.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
lf.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
lg.
All temperatures & standard interval
lh.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
li.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
lj.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
lk.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ll.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
lm.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
ln.
Reduction hub, 2.0 litres
lo.
Differential, 8.0 litres
lp.
All temperatures & standard interval
lq.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-110; GO SCA STO2A 75W-140
lr.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
ls.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
lt.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
lu.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
lv.
All temperatures & standard interval
lw.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
lx.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
ly.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
lz.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ma.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
mb.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
mc.
Reduction hub, 2.0 litres
md.
Differential, 11.2 litres
me.
All temperatures & standard interval
mf.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
mg.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
mh.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
mi.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
mj.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
mk.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
ml.
All temperatures & standard interval
mm.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
mn.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
mo.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
mp.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
mq.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
mr.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
ms.
All temperatures & standard interval
mt.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
mu.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
mv.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
mw.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
mx.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
my.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
mz.
All temperatures & standard interval; Scania 0:0, 0, 1 service types
na.
Alternative recommendations, All temperatures & extended interval; Scania 0:0, 0, 1 service types: GO SCA STO2A 75W-90; GO SCA STO2A 75W-110
nb.
Alternative recommendations, All temperatures & extended interval; all Scania service types: GO SCA STO2A 75W-140
nc.
Alternative recommendations, All temperatures & standard interval; Scania 0:0, 0, 1 service types: GO SCA STO1 75W-110
nd.
Alternative recommendations, All temperatures & standard interval; all Scania service types: GO SCA STO1 75W-140
ne.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-25°C: GO SCA STO2A 80W-90; GO SCA STO2A 80W-110
nf.
Alternative recommendations, Extended interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO2A 85W-90; GO SCA STO2A 85W-110
ng.
Alternative recommendations, Extended interval; all Scania service types, <30°C: GO SCA STO2A 75W-110
nh.
Alternative recommendations, Extended interval; all Scania service types, >-30°C: GO SCA STO2A 80W-140
ni.
Alternative recommendations, Extended interval; all Scania service types, >-10°C: GO SCA STO2A 85W-140
nj.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-25°C: VERKOL GT-8/80w90 EP; GO SCA STO1 80W-110
nk.
Alternative recommendations, Standard interval; Scania 0:0, 0, 1 service types, >-12°C: GO SCA STO1 85W-90; GO SCA STO1 85W-110
nl.
Alternative recommendations, Standard interval; all Scania service types, >-30°C: GO SCA STO1 80W-140
nm.
Alternative recommendations, Standard interval; all Scania service types, >-10°C: GO SCA STO1 85W-140
nn.
All temperatures & standard interval
no.
Alternative recommendations, All temperatures & extended interval: GO SCA STO2A 75W-140
np.
Alternative recommendations, Extended interval, <30°C: GO SCA STO2A 75W-110
nq.
Alternative recommendations, Extended interval, >-30°C: GO SCA STO2A 80W-140
nr.
Alternative recommendations, Extended interval, >-10°C: GO SCA STO2A 85W-140
ns.
Alternative recommendations, Standard interval, >-30°C: GO SCA STO1 80W-140
nt.
Alternative recommendations, Standard interval, >-10°C: GO SCA STO1 85W-140
nu.
>-37°C
nv.
Alternative recommendations: VESTA TD 3
nw.
Alternative recommendations: VESTA TD 3
nx.
Alternative recommendations: VESTA TD 3
ny.
Alternative recommendations: VESTA TD 3; ATF-D6
nz.
Alternative recommendations: ATF-D2E; VESTA TD 3
oa.
Alternative recommendations: VESTA HV 32; MULTIVESTA OP / VESTA HV 46
ob.
-40°C to -10°C
oc.
Alternative recommendations, Northern Europe: VESTA HV 22
od.
Alternative recommendations, Southern Europe: VESTA HV 32
oe.
Alternative recommendations, 40°C to 50°C: MULTIVESTA OP / VESTA HV 46
of.
-40°C to -10°C
og.
Alternative recommendations, Northern Europe: VESTA HV 22
oh.
Alternative recommendations, Southern Europe: VESTA HV 32
oi.
Alternative recommendations, 40°C to 50°C: MULTIVESTA OP / VESTA HV 46
oj.
Lithium-based
ok.
Refrigerant; With additional air conditioning, 1,450 g
ol.
Refrigerant; Without additional air conditioning, 1,000 - 1,100 g
om.
Refrigerant; Double Cab, 1,850 - 1,950 g
on.
Air-conditioning compressor oil, system total, 240 ml
oo.
Refrigerant; With additional air conditioning, 1,450 g
op.
Refrigerant; Without additional air conditioning, 1,000 - 1,100 g
oq.
Refrigerant; Double Cab, 1,850 - 1,950 g
or.
Air-conditioning compressor oil, system total, 240 ml
os.
Alternative recommendations: VESTA HV 32; MULTIVESTA OP / VESTA HV 46
ot.
Northern Europe
ou.
Alternative recommendations, Southern Europe: VESTA HV 32
ov.
Alternative recommendations, <-10°C: VESTA HVS 15
ow.
Alternative recommendations, >40°C: MULTIVESTA OP / VESTA HV 46

Oil Change Intervals

There is no Oil Change Interval data to display for this model